The b2 electronics TD60-MC is a compact Tan Delta (TD) diagnostics system for evaluating the dielectric condition of high-voltage cables. Tan Delta measurement is a proven, simple method for assessing insulation, and cables damaged by water trees can be clearly identified. b2 HVA VLF test sets with a matching voltage range, such as the HVA60, serve as its high-voltage source. It suits XLPE, PE, EPR and PILC cables and other electrical equipment.
Measurements run at variable VLF frequencies from 0.01 to 0.1 Hz, and testing and diagnostics happen at the same time. The unit runs on two D-size batteries and sends results to the PC over Bluetooth, so there is no cable to the computer and wiring stays simple. Short cables from 500 pF can be tested as well. With b2 Suite v2, the device also supports the Monitored Withstand Test per IEEE 400.2. Carried out at fixed intervals, Tan Delta testing can be the basis of a predictive maintenance programme for HV cables.
Operating voltage up to 62 kVpeak / 44 kVrms (sine wave)
Tan Delta resolution 1 × 10⁻⁵, accuracy ±1 × 10⁻⁴
Detects water-tree damage in cable insulation
Variable VLF frequency 0.01–0.1 Hz
Testing and diagnostics at the same time
Load range 500 pF to 10 µF, including very short cables
Bluetooth data transfer, no PC cable needed
Runs on two D-size batteries
Monitored Withstand Test with b2 Suite v2 (IEEE 400.2)
Works with b2 HVA VLF test sets such as the HVA60
Output voltage | 1–44 kVrms (62 kVpeak max.), sine wave |
|---|---|
Frequency | 0.1 Hz; 0.01–0.09 Hz (calibration certificate for variable frequencies optional) |
Voltage measurement | Resolution 0.1 kVrms, accuracy 1% of reading |
Current measurement | Resolution 1 µArms, accuracy 1% of reading |
Tan Delta | Resolution 1 × 10⁻⁵, accuracy ±1 × 10⁻⁴ |
Load range | 500 pF to 10 µF |
Power | 2 × D-size alkaline cells or NiMH batteries |
Interface | Bluetooth |
Compliance | IEEE 400.2, HD 620; safety EN 60950, EN 50191, EN 61010-1 |
Operating temperature | −10 to +50 °C, humidity 5–85% non-condensing |
Dimensions / weight | 300 × 280 × 640 mm / 14.2 kg |
In the box | TD60-MC test device, TD ControlCenter PC software, Bluetooth dongle, earthing cable, operating manual, transport case |
What does Tan Delta testing show?
It evaluates the dielectric condition of the cable insulation. Cables damaged by water trees can be clearly identified, and repeating the test at fixed intervals supports predictive maintenance.
Which VLF test set does the TD60-MC work with?
Any b2 HVA VLF test set with a matching voltage range, such as the HVA60. The -MC (multi-contact) design lets it extend an HVA set into a diagnostics system.
Where can I buy the b2 TD60-MC in Saudi Arabia?
From Mushor Technology, an authorized b2 electronics distributor in Saudi Arabia. Contact us by phone, WhatsApp or email for a quotation.
Which b2 diagnostics systems are similar to the TD60-MC, and how do I choose?
Choose by the test voltage you need, which should match your b2 HVA VLF test set, and by the method: PD for partial discharge, TD for Tan Delta, or PDTD for both. Similar b2 diagnostics systems:
Mushor Technology is an authorized b2 electronics distributor in Saudi Arabia. We supply the b2 electronics TD60-MC, along with b2 HVA VLF test sets and b2 PD diagnostics. Contact us for a quotation.
Related products
More in this category
Customer reviews
No reviews yet.