The b2 electronics CTL12 is a cable sheath tester and fault locator, and the first member of b2's smartCFL® family for cable fault location. It combines DC testing, fault pre-location with a high-voltage bridge, and fault pinpointing in a single device, so one field kit covers the job from sheath testing to finding the exact fault position.
It delivers up to 12 kV DC (negative polarity) and up to 50 mA, with an output load of up to 25 µF and continuous operation with no thermal limit. Pre-location runs automatically using proven bridge techniques, and a guided step-by-step workflow leads to the most suitable fault location method. With the optional CPD1 pinpointing device, whose Pulse-Lock function suppresses interference by locking onto the CTL12 pulse frequency, and foldable step voltage probes, the system gives a complete workflow from testing to precise pinpointing. The integrated NiMH battery (80 Wh) and the IP67 housing (lid closed) make it suited to remote measurement locations.
3 in 1: DC/sheath testing, fault pre-location (HV bridge) and pinpointing
Up to 12 kV DC (negative polarity), up to 50 mA adjustable
Output load and discharge capacity up to 25 µF
Automatic, high-accuracy fault pre-location
Guided step-by-step fault location workflow
One HV test lead and color-coded connectors
Integrated 80 Wh NiMH battery or 100–240 V AC supply
IP67 housing with lid closed, 12.8 kg
Dual discharge device, PE interlock, external interlock, key switch
Optional CPD1 pinpointing set with Pulse-Lock function
Output voltage | DC test 0.1–12 kV; fault pre-location (HV bridge) 0.1–12 kV; pinpointing 0.1–12 kV (negative polarity) |
|---|---|
Output current | DC test 1–50 mA; pre-location 1–25 mA; pinpointing 1–50 mA (adjustable) |
Output load | Up to 25 µF |
Duty cycle | Continuous, no thermal limitation |
Test types | DC test, fault pre-location (HV bridge), pinpointing |
Test modes | Manual mode, auto mode for fault pre-location |
Arc management | Burn on arc, trip out on arc |
Compliance | Sheath testing according to IEC 60502-2, IEC 60229, IEEE PS32 |
Metering | Voltage: 0.1 kV resolution, ±0.1 kV ±1% of reading; current: 1 / 10 / 100 µA resolution, ±10 µA ±1% of reading; resistance 0.1 MΩ–1 GΩ |
Power | 100–240 V AC, 50/60 Hz, max. 10 A; NiMH battery 80 Wh |
Safety | Dual Discharge Device (max. 25 µF), PE interlock (no HV without PE), external interlock, key switch |
Data | USB Type-C, built-in memory, reports to USB drive |
Environment | Operating −20 to +55 °C, IP67 (lid closed) |
Dimensions / weight | 417 × 221 × 334 mm / 12.8 kg |
In the box | CTL12 test set, 4 m HV test lead, grounding cable, jumper cables, colored dolphin clips, power cord, spare key, documentation on USB |
Optional | CPD1 pinpointing device set, foldable step voltage probes, foldable A-frame step voltage receiver, 80 A clamps |
What is the CTL12 used for?
Testing power cable sheaths with DC up to 12 kV, pre-locating sheath and cable faults with the high-voltage bridge, and then pinpointing the fault on site. It is aimed at utilities, service providers and industrial users who need to locate cable faults quickly and reduce outage time.
What do I need for fault pinpointing?
The CTL12 generates the pinpointing pulses. To find the exact fault position you add the optional CPD1 pinpointing device set with step voltage probes or the A-frame step voltage receiver.
Can it work without mains power?
Yes. The integrated 80 Wh NiMH battery allows operation at remote measurement locations, and it can also run on 100–240 V AC.
Where can I buy the b2 CTL12 in Saudi Arabia?
From Mushor Technology, an authorized b2 electronics distributor in Saudi Arabia. Contact us by phone, WhatsApp or email for a quotation.
Mushor Technology is an authorized b2 electronics distributor in Saudi Arabia. We supply the b2 electronics CTL12 cable sheath tester and fault locator, along with b2 HVA VLF test sets and PD and Tan Delta diagnostics. Contact us for a quotation.
Related products
More in this category
Customer reviews