The Fluke GFL-1500 Solar Ground Fault Locator is a frontline troubleshooting tool for finding active ground faults in solar photovoltaic (PV) systems. Its FaultTrack™ Technology detects the active fault and generates a traceable signal through the fault path, so the technician can follow that signal from the transmitter to the exact point of failure using non-contact tracing.
Large arrays often have incomplete or outdated string documentation. With a general understanding of the site and a few connections, the GFL-1500 identifies the faulted branch and pinpoints the fault within a string, starting from a central test location instead of disconnecting and testing each string one by one. This saves time and reduces exposure to electrical hazards.
The system has three parts: the transmitter injects the trace signal, the handheld receiver follows it with audio and visual feedback, and the signal tracing clamp identifies the faulted combiner or string without disconnections, even in electrically noisy environments. The transmitter and receiver are rated CAT III 1500 V DC / CAT IV 600 V for today's 1500 V utility-scale systems.
Finds and locates active ground faults in PV systems up to 1500 V DC
FaultTrack™ Technology: traceable signal injected along the fault path
Non-contact tracing with the receiver and signal tracing clamp
Analyze function checks for a fault and gives an approximate location from the number of modules per string
Fault function traces the signal to the physical fault location
Open Circuit function traces breaks on strings producing no current
Mapping function for arrays with missing or inaccurate documentation
Clamp isolates the faulted combiner or string without disconnections
CAT III 1500 V DC / CAT IV 600 V transmitter and receiver, built to IEC 61010
Operating voltage | Up to 1500 V DC / 600 V AC |
|---|---|
Safety rating | CAT III 1500 V DC / CAT IV 600 V (transmitter and receiver), IEC 61010-1 |
Trace signal frequency | Fault and Map 6.25 kHz; Open 32.764 kHz |
Analyze voltage range | 0 to 1500 V DC, 1 V resolution |
Analyze resistance range | From under 5 kΩ to over 1 MΩ |
Detection range through air | Up to 5.9 m (Unit mode, Fault and Map) |
Clamp current range | 150 mA AC, 0.1 mA resolution |
Clamp maximum conductor | 61 mm (2.4 in), insulated conductors up to 1500 V |
Test lead operating current | 30 A |
Transmitter | Graphic LCD, 8 × AA, IP54, about 2.04 kg |
Receiver | Segment LCD with bar graph, 4 × AA (about 16 h), IP54, about 0.27 kg |
Operating temperature | Transmitter -20 °C to 50 °C; receiver -10 °C to 50 °C |
GFL-1500 transmitter
GFL-1500 receiver
GFL-1500 signal tracing clamp
MC4 test leads, 1500 V rated
Alligator clips
MC4 unlocking tool
Soft carrying case with backpack-style shoulder strap
14 × AA alkaline batteries
Do I need complete site drawings to use it?
No. Fluke designed the GFL-1500 to work with a general understanding of the site configuration. The Mapping function helps where the documentation does not match the physical layout.
Is it a replacement for insulation resistance testing?
Fluke positions it as a dedicated tool for locating active ground faults faster, alongside existing test methods, not as a replacement for them.
Mushor Technology is the authorized Fluke distributor in Saudi Arabia. We supply the GFL-1500 for solar plant operation and maintenance teams. Contact us for a quotation.